Schenck Process VBB PWSD1 PWS PWSD1 RTB Load Cells

Product Usage :
For Belt scale weigh feeder hopper weighing application

We are here to help:Easy ways to get the answers you need.

products

Vibrating Screen
Centrifuge and Separator
Reversible Impact Hammer Crusher
Dynamic Weighing System
Weighing Indicators
Load Cell
Spare Parts

description

Schenck Process VBB PWSD1 PWS PWSD1 RTB Load Cells

Schenck VBB / Z6FC3 load cell 

 

 

Specifications:

Rated capacity

Emax

5 kg - 0,5 t

Accuracy class

 

D1

C3

C4

C6

Nominal characteristic value

Cn

2mV/V + 20µ

V/V; -2µV/V

2 mV/V ± 1 µ V/V

Combined error

Fcomb

0,05 %

0,02 %

0,013 %

0,01 %

Zero signal return after

loading (30 min)

Fdr

± 0,049 %

± 0,016 %

± 0,012 %

± 0,008 %

Creep error during stress

(30 min)

Fcr

± 0,049 %

± 0,016 %

± 0,012 %

± 0,008 %

Temperature coefficient of

zero signal

TK0

±0,05%/10 K

±0,0125%/10 K

±0,009%/10 K

±0,009%/10 K

Temperature coefficient of

characteristic value

TKc

±0,05%/10 K

±0,008%/10 K

±0,007%/10 K

±0,004%/10 K

Maximum number of incre-

ments in certified applications

nLC

1000

3000

4000

6000

Min. scale interval

vmin

0,036 %

0,009 %

0,0066 %

0,0066 %

Minimum utilisation rate

Bamin

36 %

27 %

26 %

39 %

Maximum utilisation rate

Bamax

Bamax = Emax

Input resistance

Re

350 - 480

Output resistance

Ra

356 ± 0,2

356 ± 0,12

Zero signal

S0

±1%

Maximum supply voltage

Usmax

18 V

Nominal temperature range

Btn

-10°C to +40°C

Service temperature range

Btu

-30°C to +70°C

Reference temperature

tr

23°C

Storage temperature range

Bts

-50°C to +85°C

Safe load limit

EL

150 %

Breaking load

ED

300 %

Protection class

 

IP67 (tightened test conditions: 1 m water gauge; 100 h)

Cable specification

 

3 m PVC cable, 6 wires, shielded, shield on housing

Colour code

 

black  : input  - / blue : input  + / yellow: shield

red    : output - / white : output +

grey   : sensor - / green : sensor +

Corrosion protection

 

Stainless steel

 

 

Schenck Single Point PWS Type Platform PWSD1 Load Cell


 

Schenck Process Single Point PWS Type Platform PWSD1 Load Cell for Belt Scale

Schenck Process Single Point PWS Type Platform PWSD1 Load Cell for Belt Scale

 

Schenck Ring Torsion RTB Load Cell

Schenck Process Ring Torsion Load Cell RTB C3 C6 250kg Weighing Sensor

Order No.

 

Variants

Accuracy class

 

 

C3

C3MI7,5

C6

 

0.13 t

V041085.B01

---

---

 

0.25 t

V041086.B01

---

---

 

0.50 t

V041087.B01

V041087.B03

V041087.B06

 

0.25 t MR

V041086.B07

---

---

 

0.50 t MR

V041087.B07

---

please enquire

 

Order No. Version ATEX II 2G; EEx ib IIC T6 / II 2D T70 °C

 

0.13 t

V041085.B11

---

---

 

0.25 t

V041086.B11

---

---

 

0.50 t

V041087.B11

---

please enquire

 

 

                     

 

Maximum number of load

cell intervals

For multi-divisional scales

Rated capacity

Emax

0,13 t

0,25 t

0,5 t

Accurate class

 

C3

C3

C3

C3MI7.5

C6

Sensitivity

Cn

1 mV/V ±0.1 mV/V

1.75 mV/V ±0.1 mV/V

2 mV/V ±0.1 mV/V

Combined error

Fcomb

±0.018 %

±0.023 %

±0.0115 %

Minimum dead load

output return

Fdr

±0.0167 %

±0.0167 %

±0.0066 %

±0.0083 %

Creep (30 m)

Fcr

±0.012 %

±0.0245 %

±0.0123 %

Hysteresis

 

±0.017 %

±0.0167 %

±0.0083 %

Temperature effect on zero

sensitivity per 10K

TK0

±0.008 %

---

±0.014 %

±0.007 %

±0.014 %

---

±0.009 %

±0.005 %

Temperature effect on

sensitivity per 10K

TKc

±0.008 %

±0.01 %

±0.005 %

Maximum number of load

cell intervals

For multi-divisional scales:

nLC

Z

3000

3000

7500

6000

Minimum load cell

verification interval

Vmin

Emax/17500

-----

Emax/10000          Emax/10000

Emax/20000              ---

Emax/15000

Emax/28000

Min. utilisation range

Bamin

17 %

---

30 %               30 %

15 %                 --

40 %

21 %

Max. utilisation range

Bamax

100 %

Load limit *

Ll

150 %

Max. transverse load

Lq

100 %

Input resistance

Re

1260 ±100

1100 ±50

1110 ±50

Output resistance

Ra

1020 ±0.5

1025 ±50

1025 ±25

Zero signal

S0

1%

1.5 %

1%

Supply voltage

Us

max. 30 V (recommended): 5 V … 15 V

Nominal temperature

range

Btn

-10 °C … +40 °C

Service temperature range

Btu

-30 °C … +85 °C

-30 °C … +75 °C

Storage temperature range

 

-50 °C … +95 °C

-50 °C … +80 °C

Protection class

 

IP66 / IP68

Cable specification

 

length of cable 5 m,

Screen insulated from housing (0.13 t), or

connected to housing (0.25 t – 0.50 t)

Colour code

 

Input + 82: pink    / input - 81: grey

output + 28: brown / output - 27: white

Material

 

Stainless steel

Corrosion protection

 

see table of Chemical resistance DDP8 483

Recommended torque for

attachment bolts

 

8 Nm

12 – 14 Nm

ATEX-approval

 

II 2G; EEx ib IIC T6 / II 2D T70 °C