description
Specifications:
Rated capacity |
Emax |
5 kg - 0,5 t |
|||
Accuracy class |
|
D1 |
C3 |
C4 |
C6 |
Nominal characteristic value |
Cn |
2mV/V + 20µ V/V; -2µV/V |
2 mV/V ± 1 µ V/V |
||
Combined error |
Fcomb |
0,05 % |
0,02 % |
0,013 % |
0,01 % |
Zero signal return after loading (30 min) |
Fdr |
± 0,049 % |
± 0,016 % |
± 0,012 % |
± 0,008 % |
Creep error during stress (30 min) |
Fcr |
± 0,049 % |
± 0,016 % |
± 0,012 % |
± 0,008 % |
Temperature coefficient of zero signal |
TK0 |
±0,05%/10 K |
±0,0125%/10 K |
±0,009%/10 K |
±0,009%/10 K |
Temperature coefficient of characteristic value |
TKc |
±0,05%/10 K |
±0,008%/10 K |
±0,007%/10 K |
±0,004%/10 K |
Maximum number of incre- ments in certified applications |
nLC |
1000 |
3000 |
4000 |
6000 |
Min. scale interval |
vmin |
0,036 % |
0,009 % |
0,0066 % |
0,0066 % |
Minimum utilisation rate |
Bamin |
36 % |
27 % |
26 % |
39 % |
Maximum utilisation rate |
Bamax |
Bamax = Emax |
|||
Input resistance |
Re |
350 - 480 |
|||
Output resistance |
Ra |
356 ± 0,2 |
356 ± 0,12 |
||
Zero signal |
S0 |
±1% |
|||
Maximum supply voltage |
Usmax |
18 V |
|||
Nominal temperature range |
Btn |
-10°C to +40°C |
|||
Service temperature range |
Btu |
-30°C to +70°C |
|||
Reference temperature |
tr |
23°C |
|||
Storage temperature range |
Bts |
-50°C to +85°C |
|||
Safe load limit |
EL |
150 % |
|||
Breaking load |
ED |
300 % |
|||
Protection class |
|
IP67 (tightened test conditions: 1 m water gauge; 100 h) |
|||
Cable specification |
|
3 m PVC cable, 6 wires, shielded, shield on housing |
|||
Colour code |
|
black : input - / blue : input + / yellow: shield red : output - / white : output + grey : sensor - / green : sensor + |
|||
Corrosion protection |
|
Stainless steel |
Order No. |
|
|||||||||
Variants |
Accuracy class |
|
||||||||
|
C3 |
C3MI7,5 |
C6 |
|
||||||
0.13 t |
V041085.B01 |
--- |
--- |
|
||||||
0.25 t |
V041086.B01 |
--- |
--- |
|
||||||
0.50 t |
V041087.B01 |
V041087.B03 |
V041087.B06 |
|
||||||
0.25 t MR |
V041086.B07 |
--- |
--- |
|
||||||
0.50 t MR |
V041087.B07 |
--- |
please enquire |
|
||||||
Order No. Version ATEX II 2G; EEx ib IIC T6 / II 2D T70 °C |
|
|||||||||
0.13 t |
V041085.B11 |
--- |
--- |
|
||||||
0.25 t |
V041086.B11 |
--- |
--- |
|
||||||
0.50 t |
V041087.B11 |
--- |
please enquire |
|
||||||
|
||||||||||
Maximum number of load
cell intervals
For multi-divisional scales
Rated capacity |
Emax |
0,13 t |
0,25 t |
0,5 t |
||
Accurate class |
|
C3 |
C3 |
C3 |
C3MI7.5 |
C6 |
Sensitivity |
Cn |
1 mV/V ±0.1 mV/V |
1.75 mV/V ±0.1 mV/V |
2 mV/V ±0.1 mV/V |
||
Combined error |
Fcomb |
±0.018 % |
±0.023 % |
±0.0115 % |
||
Minimum dead load output return |
Fdr |
±0.0167 % |
±0.0167 % |
±0.0066 % |
±0.0083 % |
|
Creep (30 m) |
Fcr |
±0.012 % |
±0.0245 % |
±0.0123 % |
||
Hysteresis |
|
±0.017 % |
±0.0167 % |
±0.0083 % |
||
Temperature effect on zero sensitivity per 10K |
TK0 |
±0.008 % --- |
±0.014 % ±0.007 % |
±0.014 % --- |
±0.009 % ±0.005 % |
|
Temperature effect on sensitivity per 10K |
TKc |
±0.008 % |
±0.01 % |
±0.005 % |
||
Maximum number of load cell intervals For multi-divisional scales: |
nLC Z |
3000 |
3000 7500 |
6000 |
||
Minimum load cell verification interval |
Vmin |
Emax/17500 ----- |
Emax/10000 Emax/10000 Emax/20000 --- |
Emax/15000 Emax/28000 |
||
Min. utilisation range |
Bamin |
17 % --- |
30 % 30 % 15 % -- |
40 % 21 % |
||
Max. utilisation range |
Bamax |
100 % |
||||
Load limit * |
Ll |
150 % |
||||
Max. transverse load |
Lq |
100 % |
||||
Input resistance |
Re |
1260 ±100 |
1100 ±50 |
1110 ±50 |
||
Output resistance |
Ra |
1020 ±0.5 |
1025 ±50 |
1025 ±25 |
||
Zero signal |
S0 |
1% |
1.5 % |
1% |
||
Supply voltage |
Us |
max. 30 V (recommended): 5 V … 15 V |
||||
Nominal temperature range |
Btn |
-10 °C … +40 °C |
||||
Service temperature range |
Btu |
-30 °C … +85 °C |
-30 °C … +75 °C |
|||
Storage temperature range |
|
-50 °C … +95 °C |
-50 °C … +80 °C |
|||
Protection class |
|
IP66 / IP68 |
||||
Cable specification |
|
length of cable 5 m, Screen insulated from housing (0.13 t), or connected to housing (0.25 t – 0.50 t) |
||||
Colour code |
|
Input + 82: pink / input - 81: grey output + 28: brown / output - 27: white |
||||
Material |
|
Stainless steel |
||||
Corrosion protection |
|
see table of Chemical resistance DDP8 483 |
||||
Recommended torque for attachment bolts |
|
8 Nm |
12 – 14 Nm |
|||
ATEX-approval |
|
II 2G; EEx ib IIC T6 / II 2D T70 °C |
《